구분 | 내용 |
Measuring gas | VOC gases(Benzene, Toluene, Xylene & etc) |
Measuring type | Diffusion type |
Measuring method | Photo-Ionization Detector(PID) |
Measuring range | Refer to Toxic Gas Measuring Range |
Response time | Varies by gas |
Accuracy | ±3% / Full scale |
Parameter control | Non intrusive control with a Magnet bar (calibration, maintenance) |
Operation mode display | 1-LED (Power) |
Measuring value display | LCD display (Built in back light 2-Line, 8 characters) / OLED Type (Option) |
Output signal | Analog : 4-20mA Analog Output |
Maintenance signal : 4mA |
Calibration signal : 3mA |
Fault signal : 0mA |
Digital : 2mA (HART 7, HART Device Description Language available, Option) |
Material | Housing : ALDC, SUS316(Option) |
Sensor : SUS316 |
Conduit connection | Standard : PF 3/4" |
Option : NPT 1/2", NPT3/4", M20 x 1.5P, M25 x 1.5P |
Mounting type | 2" Pole mount, Wall mount, Option |
Operating temperature | -40°C ~ 80°C |
Operating humidity | 5 ~ 99%.RH (non-condensing) |
Dimensions | 136(W) x 177(H) x 110(D)mm |
Weight | 1.5kg |